Description
Details of GYFTY Fiber Optic Cable
| SN | Item | Value |
| 1 | No. of fibers | 1-288 Core |
| 2 | Fiber | G652D or others |
| 3 | Strength Member | FRP |
| 4 | Jacket | PE, Single Sheath |
| 5 | Packing | 4kms/roll |
The Tips of GYFTY Fiber Optic Cable Installation:
Lightning Zone Safety: Utilize the all-dielectric FRP strength member to ensure complete electrical isolation in lightning-heavy or high-voltage zones.
Duct Tension Control: Monitor pulling tension to stay within the 1500N limit; use the central FRP member as the primary load-bearing element.
Bending Radius Adherence: Maintain a minimum bend radius of 20x the cable diameter during installation to prevent signal loss or tube damage.
Environment Check: Ensure the PE jacket remains intact during pulling to maintain its chemical and moisture resistance in underground ducts.
End Protection: Seal cut ends immediately with waterproof heat-shrink caps to prevent moisture ingress into the jelly-filled loose tubes.